S-415
Eco-In-Line
FEATURES
- Thermal mass flow with no additonal compensation required
- Perfect to measure your compressed air flow and consumption
- Economic and affordable compressed air flow meter – S415
- High end compressed air flow meter – S418
- Wireless communication interface for sensor settings
- Accuracy up to 1%
- Various sensor outputs: 4 … 20 mA, Modbus RTU, M-Bus
- No straight pipe requirements thanks to the integrated flow conditioner
- No by-pass measurement, measures the whole mass flow
- G inner thread connection – DN8, DN15, DN20, DN25 or DN32 (ISO 228-1)
- S418 with integrated data logger and pressure measurement
- Eco version S415: Accuracy of 3% o.RDG,measuring volume 50: 1
- Pro version S418: Accuracy of 1.5% o.RDG,measuring volume 100: 1
- Pro version S418: Integrated data loggerand integrated pressure sensor
- Real gas calibration in 2 different gases possible
PRODUCT DESCRIPTION
BENEFITS
- Convenient installation, great flexibility, can be installed anywhere
- Available as DN8, DN15, DN20, DN25 and DN32 G (female thread)
- Accuracy of 3 % o.RDG, turn down ratio 50: 1
- The economic thermal mass flow solution
The more accurate you can monitor gas flow, the more likely you will discover weak points in the process f low, thus ensuring continuity and profitability.
Asymmetric velocity profiles, swirl, and other factors caused by bends in pipes can lead quickly to inaccurate readings. And it is often not possible to place f low meters at hard-to-reach places.
The solution is our new generation of compact, easy-to-install, reliable and cost-effective flow and consumption meters: the S415.
TECHNICAL DATA
Measurement | |
Flow | |
Accuracy | 3 % o.RDG ±0.3 % FS |
Selectable units | l/min, cfm, kg/h, m3/h |
Measuring range | see table below |
Repeatability | 1 % o.RDG |
Sensor | Thermal mass flow sensor |
Sampling rate | 3/sec |
Turndown ratio | 50:1 |
Response time (t90) | 2 sec |
Consumption | |
Selectable units | m³, ft3, l, kg |
Reference conditions | |
Selectable conditions |
20 °C 1000 mbar (ISO1217)
0 °C 1013 mbar (DIN1343) freely adjustable |
Signal / Interface & Supply | |
Analog output | |
Signal | 4 ... 20 mA, isolated |
Scaling | 0 ... max flow |
Load | 250R |
Update rate | 3/sec |
Pulse output | |
Signal | Max 30 V, 200 mA |
Scaling | 1 pulse per consumption unit |
Fieldbus | |
Protocol | Modbus/RTU |
Supply | |
Voltage supply | 15 ... 30 VDC |
Current consumption | 120 mA @ 24 VDC |
General data | |
Configuration | |
Wireless | S4C-FS App for mobile phones |
Display | |
Integrated | 4 digit LED |
Material | |
Process connection | Aluminum alloy |
Housing | PC + ABS |
Sensor | Glass coated resistive sensor |
Metal parts | Aluminum alloy |
Miscellaneous | |
Electrical connection | 2 x M8 (4 pole) |
Protection class | IP54 |
Approvals | CE, RoHS, FCC |
Process connection | G-thread |
Weight | 0.45.. 1.3 kg (depends on model) |
Operating conditions | |
Medium | Air, N2 |
Medium quality | ISO 8573: 4.4.3 or better |
Medium temperature | 0 ... 50 °C |
Medium humidity | < 90 % rH, no condensation |
Operating pressure | 0 ... 10 bar(g) |
Ambient temperature | 0 ... 50 °C |
Ambient humidity | < 95 % rH |
Storage temperature | -30 ... 70 °C |
Transport temperature | -30 ... 70 °C |
Pipe sizes | DN8, DN15, DN20, DN25, DN32 |
S415
Measuring Range |
Standard Configuration | ||||
Process connection | DN8 | DN15 | DN20 | DN25 | DN32 |
Standard range (S) | 250 | 1000 | 2000 | 3500 | 6000 |
Low range (L) | 50 | 200 | 400 | 700 | 1200 |
Stated measuring ranges for S415 under following conditions:
Standard flow in air in l/min Reference pressure: 1000 mbar Reference Temperature: +20 °C
PIN ASSIGNMENT CONNECTOR FOR PLUG M8
DIMENSION
DISPLAY DIRECTION
ORDERING