S-415

Eco-In-Line

FEATURES

  • Thermal mass flow with no additonal compensation required
  • Perfect to measure your compressed air flow and consumption
  • Economic and affordable compressed air flow meter – S415
  • High end compressed air flow meter – S418
  • Wireless communication interface for sensor settings
  • Accuracy up to 1%
  • Various sensor outputs: 4 … 20 mA, Modbus RTU, M-Bus
  • No straight pipe requirements thanks to the integrated flow conditioner
  • No by-pass measurement, measures the whole mass flow
  • G inner thread connection – DN8, DN15, DN20, DN25 or DN32 (ISO 228-1)
  • S418 with integrated data logger and pressure measurement
  • Eco version S415: Accuracy of 3% o.RDG,measuring volume 50: 1
  • Pro version S418: Accuracy of 1.5% o.RDG,measuring volume 100: 1
  • Pro version S418: Integrated data loggerand integrated pressure sensor
  • Real gas calibration in 2 different gases possible

 

PRODUCT DESCRIPTION

BENEFITS
  • Convenient installation, great flexibility, can be installed anywhere
  • Available as DN8, DN15, DN20, DN25 and DN32 G (female thread)
  • Accuracy of 3 % o.RDG, turn down ratio 50: 1
  • The economic thermal mass flow solution

The more accurate you can monitor gas flow, the more likely you will discover weak points in  the process  f low,  thus ensuring continuity and profitability.

Asymmetric velocity profiles, swirl, and other factors caused by bends in pipes can lead quickly to inaccurate readings. And it is often not possible to place f low meters at hard-to-reach places.

The solution is our new generation of compact, easy-to-install, reliable and cost-effective flow and consumption meters: the S415.

TECHNICAL DATA
Measurement
Flow
Accuracy 3 % o.RDG ±0.3 % FS
Selectable units l/min, cfm, kg/h, m3/h
Measuring range see table below
Repeatability 1 % o.RDG
Sensor Thermal mass flow sensor
Sampling rate 3/sec
Turndown ratio 50:1
Response time (t90) 2 sec
Consumption
Selectable units m³, ft3, l, kg
Reference conditions
 

 

Selectable conditions

20 °C 1000 mbar (ISO1217)

0 °C 1013 mbar (DIN1343)

freely adjustable

Signal / Interface & Supply
Analog output
Signal 4 ... 20 mA, isolated
Scaling 0 ... max flow
Load 250R
Update rate 3/sec
Pulse output
Signal Max 30 V, 200 mA
Scaling 1 pulse per consumption unit
Fieldbus
Protocol Modbus/RTU
Supply
Voltage supply 15 ... 30 VDC
Current consumption 120 mA @ 24 VDC

 

 

 

General data
Configuration
Wireless S4C-FS App for mobile phones
Display
Integrated 4 digit LED
Material
Process connection Aluminum alloy
Housing PC + ABS
Sensor Glass coated resistive sensor
Metal parts Aluminum alloy
Miscellaneous
Electrical connection 2 x M8 (4 pole)
Protection class IP54
Approvals CE, RoHS, FCC
Process connection G-thread
Weight 0.45.. 1.3 kg (depends on model)
Operating conditions
Medium Air, N2
Medium quality ISO 8573: 4.4.3 or better
Medium temperature 0 ... 50 °C
Medium humidity < 90 % rH, no condensation
Operating pressure 0 ... 10 bar(g)
Ambient temperature 0 ... 50 °C
Ambient humidity < 95 % rH
Storage temperature -30 ... 70 °C
Transport temperature -30 ... 70 °C
Pipe sizes DN8, DN15, DN20, DN25, DN32

 

 

S415

Measuring Range

Standard Configuration
Process connection DN8 DN15 DN20 DN25 DN32
Standard range (S) 250 1000 2000 3500 6000
Low range (L) 50 200 400 700 1200

Stated measuring ranges for S415 under following conditions:

Standard flow in air in l/min Reference pressure: 1000 mbar Reference Temperature: +20 °C

PIN ASSIGNMENT CONNECTOR FOR PLUG M8

DIMENSION

DISPLAY DIRECTION

ORDERING

PT. August Indonesia Jaya

Jakarta :
Komplek Gading Bukit Indah Blok V No.23
Kelapa Gading – Jakarta Utara
Indonesia 14240
Telp : +62 21 2938 2790

Bandung :
Taman Holis Indah Blok E4 No. 21
Kel. Cigondewah Kidul Kec. Bandung Kulon
Bandung 40214
Telp : +62 22 2057 3429

Solo :
Jl. Ir. H. Juanda 9A RT. 02/RW. 02
Purwodiningratan, Jebres,
Surakarta 57128
Telp : +62 271 647 801

Scroll to top
X
× How can I help you?